FullAXS patch cord for Ericsson equipment
Product Description
Cable Specification
Cable mechanical properties
Cable thermal properties
Cable combustion properties
Optical characteristics single mode fiber
Cable material details
Cable properties
Metal free indoor and outdoor cable
Rodent-protected, glass-armoured
Low smoke, zero halogen and self-extinguishing
Low fire load for high safety requirement
Cable applications
For FTTA installation
For installation directly in the ground and in mechanically unprotected environments
For installation outdoor, in wet cable ducts and pipes
For installation in cable ducts
For high safety requirements in case of fire
LC connectors
FullAXS connector
Tyco or Huber+Suhner patented, color black
Break out
Jacket OD | 4.8 | mm |
Tube OD | 0.9 | mm |
Approx. weight | 26 | Kg/km |
Cable mechanical properties
Tensile strength | during installation | 450 | N | IEC 60794-1-2 E1 |
in service | 300 | N | ||
Min. bend radius | during installation | 83 | mm | IEC 60794-1-2 E11 |
in service | 30 | mm | ||
Crush resistance | short-term | 2000 | N/cm | IEC 60794-1-2 E3 |
long-term | 600 | N/cm | ||
Water penetration | h=1m,24h,P<3m | passed | IEC 60794-1-2 F5B |
Cable thermal properties
Temperature range | during installation | -40-+70 | ℃ | IEC 60794-1-2 F1 |
in service | -40-+90 | ℃ | ||
in storage | -60-+70 | ℃ |
Fire load | 0.63 | MJ/m | ||
Fire propagation | on a vertical single cable | passed | IEC 60332-1-2 | |
on a vertical cable bundle | passed | IEC 60332-3-25 |
Optical characteristics single mode fiber
Fiber standard according to ITU-T | G.657.A2 | ||
Attenuation typical (in cable) | 1310nm | ≦0.35 | dB/km |
1383nm | ≦0.35 | dB/km | |
1550nm | ≦0.21 | dB/km | |
1625nm | ≦0.23 | dB/km | |
Attenuation Maximum (in cable) | 1310nm | ≦0.4 | dB/km |
1383nm | ≦0.4 | dB/km | |
1550nm | ≦0.25 | dB/km | |
1625nm | ≦0.25 | dB/km |
Cable material details
Tight tube | Hytrel 7246 |
Reinforcement | Glass-roving water swellable |
Jacket | PE/EVA (LSZH) |
Cable properties
Metal free indoor and outdoor cable
Rodent-protected, glass-armoured
Low smoke, zero halogen and self-extinguishing
Low fire load for high safety requirement
Cable applications
For FTTA installation
For installation directly in the ground and in mechanically unprotected environments
For installation outdoor, in wet cable ducts and pipes
For installation in cable ducts
For high safety requirements in case of fire
LC connectors
Compliance | IEC 61754–20, TIA 604–10–A |
Technology | full ceramic ferrule (1.25 mm) and sleeve |
Mechanical resistance | 100 N tensile load |
Operating temperature | –40 °C to +85 °C |
Flammability | UL 94 V–0 |
Durability | 1000 mating cycles |
FullAXS connector
Tyco or Huber+Suhner patented, color black
Break out
Breakout length | On request |
Breakout cable diameter | 2.7mm |